Re: T.O.M 10 info to HV
Frank,
I just tested getting three digit variables from HV and sending thre
digit variable to HV. Although I must say that getting the correct
variable number from HV is a chalange for me as it does not always
work. I do not know why that is so. However when it does work it
will definatly work with numbers up to 255.
George
--- In ukha_xpl@xxxxxxx, "Frank Mc Alinden" <fmcalind@b...>
wrote:
> Hi George
>
> > Also it would then allow it to be put into a variable because it
> > would then be up to two or three bytes.
>
> How would you pass this via xpl-hvision ???....AFAIK ....it can
only pass
> single byte variables in a single xpl message ???......
>
> Frank
>
>
> ----- Original Message -----
> From: "gmotichka" <gmotichka@h...>
> To: <ukha_xpl@xxxxxxx>
> Sent: Friday, February 11, 2005 5:33 AM
> Subject: [ukha_xpl] Re: T.O.M 10 info to HV
>
>
> >
> >
> > Steve,
> >
> > Thanks for the insight. But -- if your code were to do the
> > calculations to F as Frank suggested, that would not violate the
> > stadard would it? I think a lot more F speeking people :) are
using
> > xPl now also.
> > Also it would then allow it to be put into a variable because it
> > would then be up to two or three bytes.
> >
> > Thanks
> > George
> >
> >
> >
> > -- In ukha_xpl@xxxxxxx, steve.cooper@u... wrote:
> > >
> > > >> I cannot see how to pass the temps from T.O.M 10
to HV
> > > > Cant see how this could be done at the moment ,as hv
variables
> > are 1 byte
> > > > and the xPL globals vary in size and the temp globals
would
be 4
> > bytes
> > > > ....In my setup i just store the temps in xPL Globals
so
hasnt
> > been a
> > > > problem...not sure if Steve can do something about
this.....
> > >
> > > As Frank says not sure how you would load something like
19.6
into
> > a
> > > variable that can have a value 0 to 255.
> > >
> > > > I think the temps are converted in Justins board to
> > C......Might be
> > > > possible for Steve to add in the tom10 config a tick
box to
> > enable F
> > > > conversion ????
> > >
> > > This is possible from a code point of view but I believe
that
> > there is a
> > > xPL standard that say all temperatures will be reported in C
to
> > avoid
> > > confusion. Not sure whether this is documented but it was
> > certainly the
> > > case from the beginning IIRC.
> > >
> > > S.
> > >
> > >
> > >
> > >
> > >
> >
_____________________________________________________________________
> > ______
> > > Authorised and regulated by the Financial Services Authority
> > >
> >
_____________________________________________________________________
> > ______
> > > The information contained in this message is confidential
and
may
> > be
> > > legally privileged. If you are not the intended recipient,
please
> > do not
> > > read, copy or otherwise use it and do not disclose it to
anyone
> > else.
> > > Please notify the sender of the delivery error and then
delete
the
> > > message from your system.
> > > Any views or opinions expressed in this email are those of
the
> > author only.
> > > Communications will be monitored regularly to improve our
service
> > and for
> > > security and regulatory purposes.
> > > Thank you for your assistance.
> > >
> >
_____________________________________________________________________
> > ______
> >
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe: ukha_xpl-subscribe@xxxxxxx
To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|