Re: Re: T.O.M 10 info to HV




Hi George

> Also it would then allow it to be put into a variable because it
> would then be up to two or three bytes.

How would you pass this via xpl-hvision ???....AFAIK ....it can only pass
single byte variables in a single xpl message ???......

Frank


----- Original Message -----
From: "gmotichka" <gmotichka@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Friday, February 11, 2005 5:33 AM
Subject: [ukha_xpl] Re: T.O.M 10 info to HV


>
>
> Steve,
>
> Thanks for the insight. But -- if your code were to do the
> calculations to F as Frank suggested, that would not violate the
> stadard would it? I think a lot more F speeking people :) are using
> xPl now also.
> Also it would then allow it to be put into a variable because it
> would then be up to two or three bytes.
>
> Thanks
> George
>
>
>
> -- In ukha_xpl@xxxxxxx, steve.cooper@u... wrote:
> >
> > >> I cannot see how to pass the temps from T.O.M 10  to HV
> > > Cant see how this could be done at the moment ,as hv
variables
> are 1 byte
> > > and the xPL globals vary in size and the temp globals would
be 4
> bytes
> > > ....In my setup i just store the temps in xPL  Globals so
hasnt
> been a
> > > problem...not sure if  Steve can do something about
this.....
> >
> > As Frank says not sure how you would load something like 19.6
into
> a
> > variable that can have a value 0 to 255.
> >
> > > I think the temps  are converted in Justins board to
> C......Might be
> > > possible for Steve to add in the tom10 config a tick box to
> enable F
> > > conversion ????
> >
> > This is possible from a code point of view but I believe that
> there is a
> > xPL standard that say all temperatures will be reported in C to
> avoid
> > confusion.  Not sure whether this is documented but it was
> certainly the
> > case from the beginning IIRC.
> >
> > S.
> >
> >
> >
> >
> >
> _____________________________________________________________________
> ______
> > Authorised and regulated by the Financial Services Authority
> >
> _____________________________________________________________________
> ______
> > The information contained in this message is confidential and may
> be
> > legally privileged. If you are not the intended recipient, please
> do not
> > read, copy or otherwise use it and do not disclose it to anyone
> else.
> > Please notify the sender of the delivery error and then delete
the
> > message from your system.
> > Any views or opinions expressed in this email are those of the
> author only.
> > Communications will be monitored regularly to improve our service
> and for
> > security and regulatory purposes.
> > Thank you for your assistance.
> >
> _____________________________________________________________________
> ______
>
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>



xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe:  ukha_xpl-subscribe@xxxxxxx
To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx

xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.