Re: T.O.M 10 info to HV
Hi Steve
> This is possible from a code point of view but I believe that there is
a
> xPL standard that say all temperatures will be reported in C to avoid
> confusion......
Not much good to people tho who are used to reading the temp in F........
is
it possible to get xpltom10 to add the C or F to the reporting of each
sensor ...???......Default ... C.... but have the tick box for F...in the
config section ...????
Frank
----- Original Message -----
From: <steve.cooper@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Thursday, February 10, 2005 8:49 PM
Subject: Re: [ukha_xpl] T.O.M 10 info to HV
>
>
> >> I cannot see how to pass the temps from T.O.M 10 to HV
> > Cant see how this could be done at the moment ,as hv variables
are 1
byte
> > and the xPL globals vary in size and the temp globals would be 4
bytes
> > ....In my setup i just store the temps in xPL Globals so hasnt
been a
> > problem...not sure if Steve can do something about this.....
>
> As Frank says not sure how you would load something like 19.6 into a
> variable that can have a value 0 to 255.
>
> > I think the temps are converted in Justins board to C......Might
be
> > possible for Steve to add in the tom10 config a tick box to
enable F
> > conversion ????
>
> This is possible from a code point of view but I believe that there is
a
> xPL standard that say all temperatures will be reported in C to avoid
> confusion. Not sure whether this is documented but it was certainly
the
> case from the beginning IIRC.
>
> S.
>
>
>
>
>
___________________________________________________________________________
> Authorised and regulated by the Financial Services Authority
>
___________________________________________________________________________
> The information contained in this message is confidential and may be
> legally privileged. If you are not the intended recipient, please do
not
> read, copy or otherwise use it and do not disclose it to anyone else.
> Please notify the sender of the delivery error and then delete the
> message from your system.
> Any views or opinions expressed in this email are those of the author
only.
> Communications will be monitored regularly to improve our service and
for
> security and regulatory purposes.
> Thank you for your assistance.
>
___________________________________________________________________________
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe: ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe: ukha_xpl-subscribe@xxxxxxx
To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|