Yep - make sure that you run TX and RX over twisted pairs - so, for
example, connect Orange to TX, Orange/White to ground at each end and
Blue to RX, Blue/White to Ground also
:)
Should do the trick - I had something similar here with VFDs
Ian.
-----Original Message-----
From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
Of Paul Gale
Sent: 13 July 2005 21:31
To: ukha_d@xxxxxxx
Subject: [ukha_d] Serial connection over Cat5 getting corrupted
I've just wired up my aquarium computer (RS232) via my structured Cat5
cabling back to node0. I guess there's about 10-15m in the run.
The trouble is, I'm getting some corruption in the sent data - spurious
characters and line feeds missed off.
Any ideas what I can do to improve the comms?