The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: Mac mini - two monitors different resolutions?!


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Swish 400 Control using relays...



Ian,

is the relay in the AM12 also buzzing?

If yes, you can disable local control by:
1:  removing a jumper wire in the proximity of the chip 78570,
it connects to pin 7.
2: remove R3 (330K) resistor, connected to the red wire.

If not, then it is probably not a local control issue but
a leaking problem coz the load is too small.
In this case I would try to disconnect all feedback
to the chip. In the module I have here there is a red wire
going from the relay contact back to the PCB.
It should work if you disconnect this one.

Hope this helps,
Luc.

> Basically, the relay when turned on behaves nicely, however, when you
turn
> it off, the relay buzzes, switching at a very familiar sounding 50Hz.




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.