Re: Where can I find RJ-11 to RS232 Cable for my Powerline Interface?
Thanks. But, what has this got to do with a cable I am trying to find?
"Charles Sullivan" <cwsulliv@xxxxxxxxxxxx> wrote in message
news:pan.2005.10.23.04.10.28.316016@xxxxxxxxxxxxxxx
> The same comments apply to the TW523. All you send/receive
> with these devices is a string of pulses, not encoded per
> RS232. It's a synchronous protocol since the timing signal
> (zero crossing pulses) is provided, as opposed to the asynchronous
> RS232 protocol.
>
> On Sun, 23 Oct 2005 01:14:46 +0000, jt wrote:
>
>> I have the TW523.
>>
>> "Charles Sullivan" <cwsulliv@xxxxxxxxxxxx> wrote in message
>> news:pan.2005.10.22.23.14.58.917596@xxxxxxxxxxxxxxx
>>> On Sat, 22 Oct 2005 19:35:24 +0000, jt wrote:
>>>
>>>> I purchased 2 way powerline interface PSC05 and no cable came with it.
>>>> I
>>>> need the RJ11 to RS232.
>>>>
>>>> Anywhere I can find this cable to purchase?
>>>>
>>>> Thanks,
>>>> JT
>>>
>>> I hope you understand that the PSC05 input/output is not data
>>> compatible with RS232. I suppose it might be possible to operate
>>> it by custom wiring its input and output lines to status pins
>>> on a PC serial port and writing custom software to read/write the
>>> pulses on these pins, but I suspect that's not what you're after.
>>>
>>>
>>>
>>>
>