[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Trying to work with a CM11A under Linux



You are misreading the documentation. 0xa5 is requesting that you reset the
RTC. You can send 0x9b alone or followed by the 7 bytes of RTC data as
defined in section 8 of the document.

Anthony Toft <toftat@xxxxxxxxxx> wrote:

>Hi folks...
>
>Well the idea of computer control of my appliances has finally gotten to
>me and I bought a CM11A.
>
>I am trying to write "x10d" for my linux machine (it will provide remote
>access to the appliances) and my CM11A is responding with 0xa5, meaning it
>would like me to download 42 bytes of macro definitions. I am not using
>macro's so I sent it 42 0x00 but that won't stop the complaining.
>According to the protocol doc, it will not work until I get it to stop
>asking for the macro.
>
>Does anyone here have a suggestion to resolve this problem.
>
>TIA
>
>Anthony