[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Insteon Review
I haven't found a way to inject high level noise on the line. A low level
(~45mV) 131.7kHz CW signal does not hinder Insteon operation but a higher
level might.
All in all I'm impressed with Insteon and think it is worth consideration
with two caveats.
One: The weakest point is the 900MHz RF links which serve as a phase
bridge. They need to be fairly close together and are subject to
interference from other 900MHz devices.
Two: SmartHome has a poor track record so other flaws may appear under more
intensive use.
The two-way protocl is reliable (subject to caveat one) and reliability
should get better as modules are added since each module acts as a PLC
repeater.
Signal suckers will still require filters. Noise sources may not be as much
of a problem as they are for X-10.
The initial price point is competitive with X-10. If that remains true as
they expand the number of modules and devices I think it has a chance to
displace X-10.