Re: Napco GEM-P9600 Strange Behavior After Power Outage



On Thursday, February 18, 2021 at 8:31:44 PM UTC-5, wallywald...@xxxxxxxxx =
wrote:
> Lost power for extended period of time. Battery went dead. I have an Expa=
nsion Zone Module (EZM) and three partitions configured on the 9600.=20
>=20
> After power was restored, the following things are occurring:=20
> 1-The EZM red LED is solid and the module is beeping every 34 seconds.=20
> 2-The keypad for the primary partition says **Zones Faulted** and it then=
 proceeds to display each of the following numbers, one at a time, of: 01-,=
 02-, 03-,....08-. It then repeats this continuously.=20
> 3-The keypads for the other two partitions are continuously displaying '0=
2-Out of System' and '03-Out of System' respectively.=20
>=20
> Any ideas what has happened and how to fix it?
If the system doesn't totally lose power and then power returns, the micro =
processor can come back on line with a "scramble" memory. Remove power (bot=
h AC and battery) let it sit for a few minutes, then reapply power, AC firs=
t and battery quickly afterwards. The system should come back up with all s=
ystems normal except it will show you a low battery. If the battery was in =
decent shape before the power failure, it may take 24 hours or more for it =
to recharge so you may have to press the reset button a few times until it =
recharges. If the battery wasn't in good shape, then you'll have to replace=
 it if it doesn't recharge.