Re: VISTA 12D



On 8 =CC=DC=FA=EF=F2, 14:57, nick markowitz <nmarkow...@xxxxxxxxx> wrote:
> On May 8, 7:25=A0am, proguard <sp.kintzoni...@xxxxxxxxxxx> wrote:
>
> > Recently i did *97 1 at an Ademco Vista 12D panel in order to reset
> > default values but after that the keypad is "dead"! It dispalys
> > nothing! Any idea?
>
> > Thanks!
>
> never heard of a 12 D but if default command went thru it probably
> does not recognize the address for the key pad.
>
> most newer series panels need first initial keypad set at address =A016
> or 00 =A0 if not the display will be blank.
>
> check address by pushing and releasing 1 and 3 together =A0if =A0 not 16
> or 00 =A0then power down keypad =A0power up hit 1 and 3 together release
> press in correct address then star and it should display default data
> properly.

Thanks dear Nick. I put keypad at address 16 and it works again. At
address 00 it displays nothing. So it works only at add 16.
After *97 the keypad went at address 17 thats why.