[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: VISTA 12D
On May 8, 7:25=A0am, proguard <sp.kintzoni...@xxxxxxxxxxx> wrote:
> Recently i did *97 1 at an Ademco Vista 12D panel in order to reset
> default values but after that the keypad is "dead"! It dispalys
> nothing! Any idea?
>
> Thanks!
never heard of a 12 D but if default command went thru it probably
does not recognize the address for the key pad.
most newer series panels need first initial keypad set at address 16
or 00 if not the display will be blank.
check address by pushing and releasing 1 and 3 together if not 16
or 00 then power down keypad power up hit 1 and 3 together release
press in correct address then star and it should display default data
properly.