[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Alarm System Transformer
Well here is the rub. A 40 VA transformer is going to have a fusible link
inside nearly always. A 20 VA most likely not. If you popped a 20 VA because
of a problem then you might smoke a 40 VA in an instant.
For a few extra bucks you can get a self restoring transformer. The rub
there is that certain alarm panels (like Bosch G Series) go nuts with a self
restoring transformer.
"H Brown" <hehbr2011@xxxxxxxxx> wrote in message
news:c3332c00-f2fd-4c48-b1e4-34c613b64edb@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> My home alarm system transformer is dead. Parameters off the unit say
> 16.5 VAC, 20VA. I found a replacement unit that has 16.5VAC, 40VA. I
> think the 40 VA is 40 watts output which I believe should work since
> my previous transformer only put out 20 watts. Correct?
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home