[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: alarm questions for DSC PC2500



Mark Leuck wrote:
> "Stanley" <stanigator@xxxxxxxxx> wrote in message
> news:851f675a-c578-4801-98a7-6e10f2074cb8@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>> On Jan 10, 7:55 am, Frank Olson
>> <use_the_email_li...@xxxxxxxxxxxxxxxxxxxxxx> wrote:
>>> Stanley wrote:
>>>> Frank: I have checked the fuses. They are still conducting and
>>>> runnable.
>>> OK...  The "last step" in the troubleshooting process involves
>>> connecting the keypad directly to the control.  Power down the system
>>> and disconnect it from the wires in the wall.  Then connect it directly
>>> to the keypad terminals on the main board and power the system back up.
>>>   If the same LED's light and the keypad remains unresponsive, I would
>>> suggest that the system (or the keypad) is "hooped".  It would be fairly
>>> easy to replace the system with one of the newer "Power" series panels
>>> from DSC.  Contact a friendly local dealer who's amenable to selling you
>>> a new panel or one of the online dealers located here:
>>>
>>> http://www.yoursecuritysource.com/buyingonline.htm
>>>
>>> Good luck!!
>> I have an appointment with an alarm monitoring company to change the
>> entire system today.
>
> Best idea I've heard so far
>
>


Ditto!


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home