Re: NX8E keyswitch
On 2 =CE=91=CF=8D=CE=B3, 01:38, Bob <s...@xxxxxx> wrote:
> proguard wrote:
> > On 1 =C3=81=C3=BD=C3=A3, 18:36, Bob <s...@xxxxxx> wrote:
> >> Proguard Security wrote:
> >>> At one of my NX8E installations i added a keyswitch at zone 21 (on ex=
panders
> >>> Z13) and i programmed it as momentary keyswitch (11). I connect the N=
C-C
> >>> relay output from the wireless receiver but nothing happens... Nor ar=
m-nor
> >>> disarm... :-( Am i missing something??
> >>> Thanks in adnavce...
> >>> Spyros - Thessaloniki - Greece
> >> r u using resistor?
>
> > I've got only one partition. Z9-Z16 with zone double and Z17-Z24 with
> > expander. Yes, i use 3.3k resistors at expander's zones including Z21
> > (keyswitch zone).
>
> I have not used keyswitch arming with an nx panel. =C2=A0I am guessing th=
at
> the keyswitch has to be on the NX panel. =C2=A0not the expansion board. =
=C2=A0the
> following quote from a manual:
>
> "Any zone on the NX-8E-CF can be programmed as a keyswitch zone. If this
> is done, a
> momentary short on this zone will arm/disarm the control. If
> opening/closing reports are
> sent, the user code will be 99."
This was one of my thoughts... I'll try out to manually short onboard
z14 (it is spare) and i'll let you know in order to learn if we can
use only the onboard zones for keyswitch operation.