Re: NX8E keyswitch
proguard wrote:
> On 1 Áýã, 18:36, Bob <s...@xxxxxx> wrote:
>> Proguard Security wrote:
>>> At one of my NX8E installations i added a keyswitch at zone 21 (on expanders
>>> Z13) and i programmed it as momentary keyswitch (11). I connect the NC-C
>>> relay output from the wireless receiver but nothing happens... Nor arm-nor
>>> disarm... :-( Am i missing something??
>>> Thanks in adnavce...
>>> Spyros - Thessaloniki - Greece
>> r u using resistor?
>
> I've got only one partition. Z9-Z16 with zone double and Z17-Z24 with
> expander. Yes, i use 3.3k resistors at expander's zones including Z21
> (keyswitch zone).
I have not used keyswitch arming with an nx panel. I am guessing that
the keyswitch has to be on the NX panel. not the expansion board. the
following quote from a manual:
"Any zone on the NX-8E-CF can be programmed as a keyswitch zone. If this
is done, a
momentary short on this zone will arm/disarm the control. If
opening/closing reports are
sent, the user code will be 99."