Re: Napco Wireless Reporting



No need to do that. here are the reports.


12:04:40 TESTING OF ENTIRE SYSTEM - DELETED
                      FROM TUE 12/05/06 AT 1108 TO TUE 12/05/06 AT 1308
                      * REASON:PER JAMES
                      * DONE
         15:04:59 SIGNAL RECEIVED:  (E333 ) E333   0
                  TROUBLE EXPANSION MODULE FAILURE
         16:36:42 SIGNAL RECEIVED:  (E333 ) E333   0
                  TROUBLE EXPANSION MODULE FAILURE
         16:56:42 SIGNAL RECEIVED:  (E306 ) E306   0
                  PANEL PROGRAMMING CHANGED ZONE 0
         18:49:19 SIGNAL RECEIVED:  (E333 ) E333   0
                  TROUBLE EXPANSION MODULE FAILURE
         21:01:32 SIGNAL RECEIVED:  (E333 ) E333   0
                  TROUBLE EXPANSION MODULE FAILURE
         22:57:37 SIGNAL RECEIVED:  (E333 ) E333   0
                  TROUBLE EXPANSION MODULE FAILURE




"Bob La Londe" <nospam@xxxxxxxxx> wrote in message
news:47051325$0$26463$88260bb3@xxxxxxxxxxxxxxxxxxxx
> "Just Looking" <nospam@xxxxxxxxxx> wrote in message
> news:47051972$0$20564$4c368faf@xxxxxxxxxxxxxxxxx
> > Yes it does send by zone on low battery. What I said was it didn't send
by
> > zone (GEM 9600) when it misses a transmitter check it signal. In Contact
> ID
> > that only reports as a generic expansion module failure.
>
> Hmmm...  I don't think I've got any 9600s running wireless, but I'm sure I
> can emulate a sensor polling failure and see exactly what it does on a
> P1632.  One thing I can say is that I noticed some inconsistency in how
> P9600s operate and handle some things a few years back when they were
> changing versions.  I do have a 9600 in my house.  I suppose I could stick
> on a receiver just to test what happens and see what it reports exactly.
>
>
>
>
>
>
> >
> > "Bob La Londe" <nospam@xxxxxxxxx> wrote in message
> > news:4705089f$0$18339$88260bb3@xxxxxxxxxxxxxxxxxxxx
> > > Yes it does send detailed information. This is cut and pasted directly
> > from
> > > the CS log for a P1632.
> > >
> > > Thu 10/04/07 04:38:41     TROUBLE-REST> Area #1-370: (#30) (PROTECTION
> > LOOP)
> > >
> > > Thu 10/04/07 03:39:30 SYS SERVICE>
> > >    >SENT: AUTOMATIC DEALER NOTIFICATION
> > >
> > > Thu 10/04/07 03:39:27     TRBL-SUP> Area #1-384: (#30) (SENSOR LOW
BATT)
> > >
> > >
> > >
> > > --
> > > Posted via a free Usenet account from http://www.teranews.com
> > >
> >
> >
>
>
>
> --
> Posted via a free Usenet account from http://www.teranews.com
>