Re: ademco vista 20p



OC open  circuit.
This happened to me while relocating a keypad just yesterday.
Connect the keypad with a short piece of wire to the control.
If it works then check the run to the keypad's location.
My problem was a broken data wire ( could be the green or yellow)
dr
"Jim Rojas" <jrojas@xxxxxxxxxxxx> wrote in message
news:473920e8$0$26379$88260bb3@xxxxxxxxxxxxxxxxxxxx
> It looks like your keypad is not addressed properly.
>
> 1. Power the system down & up again.
> 2. Press and hold the 1 and 3 buttons until you see an address number.
> 3. If the address is not 16, Press 16 then *.
> 4. That should get your keypad functional.
>
> Jim Rojas
>
>
>
> isafdomm wrote:
>> i have a vista 20p and a ademco 6160 and when i power up the alarm it
>> reads
>> open ckt . it even reads that with nothing hooked up except keypad
>>
>
> --
> Posted via a free Usenet account from http://www.teranews.com
>