Not that familiar with DSC, but if the panic fire is from the keypad..have
you hardened the keypad run?
Ground only one side of the shield...but you would know that being a ham.





"MikeSus" <mikesus@xxxxxxxxx> wrote in message
news:1183549011.863308.169320@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| Has anyone hardened a DSC System against RFI?  I am an amateur radio
| operator and had a problem on almost all frequencies until I put in .
| 001 mfd caps on each loop, and put a snap on choke around the hardwire
| lines.  Now the only problem is when I transmit on 80m (3.700Mhz)
| After a short while of transmitting, I get an expansion module failure
| message and then a panic fire.  I do have the wireless Fire Alarm and
| thought it could be gating, but that would not explain the expansion
| module failure message.  Any ideas?
|