[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Ademco Vista-10SE Chime does not chime
Is the zone programmed as an entry/exit or perimeter?
Enter your code, then "test" If it beeps then, its probably a programming
error
"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:46895eba$0$3572$815e3792@xxxxxxxxxxxxxxxxx
> Ok...but is ANYTHING else on the same zone with that door? For instance if
> there are 6 windows and that door on zone 3, and one of those windows is
> left opened the DOOR will not chime.
>
> Does ANYTHING else chime?
>
>
>
> "SmithRan" <mantram@xxxxxxxxx> wrote in message
> news:1183385994.523183.178820@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> |
> | Is "Chime" displayed in the keypad? - Yes it is.
> |
> | Is something else opened on that zone? - Chime shows up in the keypad,
> | and when i open a door the keypad shows that the door (including zone
> | #) is opened - but no sound.
> |
> |
> | Thanks for taking time to ask about the problem.
> |
> |
> |
> |
> |
> | On Jul 2, 1:17 am, "Crash Gordon" <webmas...@xxxxxxxxxxxxxxxxxxxxx>
> | wrote:
> | > Is "Chime" displayed in the keypad?
> | >
> | > Is something else opened on that zone? - if there's something else on
> that
> | > loop that's opened the door's not gonna chime.
> | >
> | > "SmithRan" <mant...@xxxxxxxxx> wrote in message
> | >
> | > news:1183350966.115040.288420@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> | > |I have a Ademco Vista-10SE unit where everything works perfectly from
> | > | the alpha keypads, but when i set the unit to Chime (sound on door
> | > | open without alarm), it does not chime - even though the display
> shows
> | > | that the door has been opened.
> | > |
> |
> |
>
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home