Re: Quality Ademco Engineering



the 6160 does not work on the older vista 50's either.  :(


James B


"Mark Leuck" <m..leuck@xxxxxxxxx> wrote in message
news:461ee6e1$0$5625$4c368faf@xxxxxxxxxxxxxxxxx
>
> "Nomen Nescio" <nobody@xxxxxxxxx> wrote in message
> news:b949928bdf3e670b2af55a18ee9423be@xxxxxxxxxxxx
>> Mark Leuck wrote:
>>
>> >Which older panels? It works with all the panels the 6139 keypads worked
>> >with
>>
>> You would think so, but you'd be wrong.  The 6160 does not work on the
>> XMPT2.
>> The 6139 does.   I'm guessing the XMP has the same problem, but I haven't
>> verified that.
>>
>> The 6160 will display correctly, but  the panel won't respond to keypad
>> data from a 6160.
>>
>> Oops.
>
> As far as I know the XMP wouldn't work with either 6139 or 6160 anyway.
> And
> I don't consider that much of an oops when the vast majority of the later
> stuff will, I've run into maybe 1 XMPT2's in my life.
>
> Now if it was say the original Vista-10 I'd agree
>
>