Both the DSC PC1555 (discontinued a few years ago) and the PC1555MX [a.k.a.
Power 632] (now replaced by the Power 1616) have an event buffer. It would
be a simple matter to see what the problem was and when it happened by
uploading it. Company X could have done that without sending a technician to
the job.
As far as the installation part goes the only thing you can put in return
air ducts, when its otherwise legal, is plenum wire. Certainly not a control
panel or even a siren speaker. I can't begin to guess how many code
violations that system you describe would add up to. And the installation of
a single smoke detector? When is that ever okay? Substituting an Ademco Lynx
for a DSC? A Lynx system (kit) is more expensive than a DSC (kit) so she got
shortchanged there. That falls under deceptive trade practices I believe.
Doesn't your state have burglar and fire alarm licensing requirements? Ours
does. I'd turn them in, then go fishing. Alarm dealers like that ruin it for
everyone.

 "Bob La Londe" <nospam@xxxxxxxxx> wrote in message
news:450cd3b5$0$19726$88260bb3@xxxxxxxxxxxxxxxxxxxx
> Ok...  I admit it.  I have once or twice.  It always bites me in the ass.
>
> The latest one was a joke.
>
> Company X calls me and says, can you help us out we are a small company
> with a few accounts in Yuma.  I should said no.  They are an ex-ADT dealer
> with over a hundred lick and stick systems in Yuma.
>
> I felt sorry for the littel old lady they sold it to, but she really got a
> typical $0 down system.  2 doors and a motion sensor.  They threw in a
> smoke and a remote for good measure.
>
> Company X told me they had a PC5010 down there.  I stopped by Jim's site
> and downloaded all the PC5010 manuals and stored them on my laptop so I'ld
> have refferences with me on-site.  When I got there I couldn't find the
> panel. Finally we located it inside the return air duct.  It wasn't a
> PC5010.  It was a PC1555.  During the course of our conversaton the lady
> pulled out all her paperwork and showed me where they had sold her a Lynx.
>
> Dang.
>
> P.S.  Found.
>
> Magnet falling out of sliding door.
> No RJ-31X
> Panel inside return air duct.
> Cause of actual trouble unknown, and not indicated on the keypad.
>
> and
>
> THEY DON'T KNOW IF THEY HAVE ANY CENTRAL STATION HISTORY INDICATING THE
> CAUSE OF THE TROUBLE INDICATION.
>
> I left them a message about all the things I found wrong, and that I
> wasn't interested in doing any further work for them.  I don't do installs
> like that and sure as heck don't want to service them.  THEY CALLED ME
> BACK THE NEXT DAY FEELING AROUND IF I WOULD GO OUT AGAIN.
>
> I have not invoiced them and probably won't.  I would be ashamed to have
> any proveable association with that system.
>
>
> --
> Bob La Londe
> Fishing Arizona & The Colorado River
> Fishing Forums & Contests
> http://www.YumaBassMan.com
>
>
>
> --
> Posted via a free Usenet account from http://www.teranews.com
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home