Another; Oye
Doing a cleanup on a system for a 2 million dollar house, alarm installed by
a moonlighting cop. System's been in for at least a year;
Vista 15P
absolutlely no logic to zoning...it was like whomever trimmed it whatever
wires he grabbed that was what went in that zone. Delay doors were also MBR
windows, doors, etc. zoning jumped from a window on this side of the house
to a door on the other side of the house - insane.
of course two conductor to doors/windows.
3 zones were programmed as zone type 4;
both pirs - ok, another zone with windows and the WORST...zone 5 the smokes
were zone type 4.
4 wire smokes powered by keypad power, eol at zone 5 and no supervision
relay.
another zone was zone type 5 and that was a door and a window - huh? why?
6 zones for a 6000 sq ft house and a separate gymnasium building which
wasn't programmed into the system at all - it was like; fuck it we can't
make it work take it out.
oh yeah, a 5881H running only 2 keyfobs?
this kinda shit gives me a migraine