Re: Alarm code help - DSC 433
<dumbkid0@xxxxxxxxx> wrote in message
news:1149219405.797614.54950@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> That's so strange. Zone 1 and Zone 4 are not battery operated
> contacts. They are magnetic contacts for doors, with 22 gauge wires
> direct to the panel.
>
> Is it possible to reset/clear the trouble led and see if it will come
> up again?
>
> Thanks so much in advance.
>
> Tom
>
Umm... ok? In that case, here's a couple possible problems...
- ESN numbers programmed into zones 1 and 4
- Option 8 enabled in sections 101 and 104
To clear the troubles, at least temporarily, power the system down and back
up again (ac down, battery down, wait 30 seconds, battery up, ac up). If
you're lucky, they won't come back.
You can also try the supervisory reset... *8, installer code, 902, wait 1
minute, 903, # #