[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Scantronic 9800 bF every 5 minutes



Thanks both,

I took the control panel off the wall on Saturday night and found there
was a volume control inside for internal alarm, I turned it down to
nothing so that we could sleep at night. Strangely this has stopped the
bF fault from coming on........

I will see if I can get a battery today.

Colin

BIG NIGE wrote:
> "Paul Ekins" <pmekins@xxxxxxxxxxxxxxxxxxxx> wrote in message
> news:84lug.6337$i32.587@xxxxxxxxxxxxxxxxxxxxxxx
> > You will need to open the main box, probably in the airing cupboard or
> > somewhere similar. You will trigger the tamper but you will be able to
> > stop sounders with your code. Replace battery and reset system. I would
> > advise a 7Ah battery, it may be bigger than the one you have at the moment
> > but it will last longer in the case of power failure
> >
> >
> > --
> > Paul Ekins
> >
> > Linc Secure
> > Ph: 0845 123 2599
> > paul@xxxxxxxxxxxxxxxx
> > www.lincsecure.co.uk
> >
> Everything as Paul Says
>
> Just be careful that the battery is clear of the lid screwholes when
> re-fitting.



alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home