[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Paragon Plus - mains spike
My previous reply is making the assumption that your code number still
works.
If it does not then try 1234, If this does work then this means that the
panel programming has been defaulted and the system will need to be
re-programmed.from scratch.
"BIG NIGE" <no.way@xxxxxxxxxxxxxxxx> wrote in message
news:B44Se.5186$Ys5.2453@xxxxxxxxxxxxxxxxxxxxxxx
> The jumper is a dead short.
>
> Shorting the mains fail pins will allow the panel to be set when the mains
> fails (running on battery only).
>
> There is no point in shorting these if the problem is a tamper fault.
>
> You need to locate the tamper fault. This could be either the main
control
> unit lid tamper switch, The global tamper circuit or the Siren tamper
> circuit. There is also the possibility that the fault is on the circuit
> board but this is the least likely and the last thing to try.
>
> Firstly remove the connections to the global tamper circuit on the pcb and
> short out with a short length of wire.( T T )
> Hold lid tamper switch closed and try to set system if tamper fault gone
> then the fault is somewhere on this circuit.
>
> If fault still there short out Siren tamper connections ( B- BT ) and try
> again (this is the most likely offender).
>
>
>
> <phillip.mackey@xxxxxxxxxxxxx> wrote in message
> news:1125680999.859036.261030@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> > I was hoping to avoid that expense. The panel and PIRs appear to be
> > functioning OK.
> >
> > I was going to try a reset first and see where that takes me.
> >
> > Any Idea as to what the jumper is and what the procedure is?
> >
>
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home