Re: DLS 2002 not "seeing" LCD5500Z keypad



Slot 8 should fix it,  The downloader only goes to keypad 8 for some reason.

James

"Doug L" <vssdoug@xxxxxxx> wrote in message
news:cMednah27M9B49HenZ2dnUVZ_sydnZ2d@xxxxxxxxxxxxxxx
> Try assigning it to slot 8 instead of slot 1
>
> Doug L
>
> --
>
> "Robert" <rdturner0@xxxxxxxxx> wrote in message
> news:1129079646.357708.320400@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> > For some strange reason, I cannot get the DLS 2002 SP2 software to see
> > an LCD5500Z keypad. It sees the keypad in general (in that the "system
> > graphic" contains a keypad, but it shows it as an LCD5500), but will
> > not allow programming of the keypad (i.e. all the text labels, etc).
> > I've tried adding the keypad to the account explicitly, with the
> > correct version (3.1), but the DLS software always rejects it and
> > recommends removing it from the account. Even if I force it to leave it
> > on the account, it won't communicate with it.
> >
> > The keypad is in partition 1, slot 1. The panel does seem to see the
> > keypad and the keypad functions properly as far as I can tell. It's as
> > though the panel doesn't think the keypad is a Z model (LCD5500Z) and
> > thinks it's a regular fixed message/icon keypad (LCD5500).
> >
> > Anyone got any ideas?
> >
> > Thanks in advance for any suggestions people might have.
> >
> > Robert
> >
>
>