Re: Multiple magnets, one zone, EOL resistor. Never works!



Many of the panels I have worked on take a 1K ohm resistor.

Be sure you are using the correct value resistor for your panel.

Also try putting just a resistor (of correct value) on the terminals with
the wires removed.

When wiring a building/house, etc. It is a good idea to bring separate wires
to a junction point.

Then what you can do is first get just the resistor working on the panel.
Then add just one contact and get that working. Then add another and
another. (Isolate the problem...)