[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Question about Napco 8-zone expander
Bob,
Can you program the P800 from a laptop without using the external Napco
Modem???
Russ
"Bob La Londe" <usenet@xxxxxxxxxxxxxxxxx> wrote in message
news:LpKdnRTjT72mTcbeRVn-qg@xxxxxxxxxxxxxxx
>
> "jewellfish" <jewellfish@xxxxxxxxx> wrote in message
> news:1130071694.226929.73130@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>> Yes, it is required to use EOLRs on that module for unused zones and
>> all zones, for that matter, unless you reconfigure the zones in PCD
>> software. If you configure them as "No EOL required" then you can
>> simply use a jumper across the unused zones. I do not beleive that
>> this programing option can be done from the keypad.
>>
>> Regards
>
> It can be done from address programming. Not from quick mene programming
> though.
>
>
>
>
>> Crash Gordon wrote:
>>> I know some panels (dunno abt Napco as I'm not partial to them) if you
>>> program the zone out and don't put a eol on when you remotely view
>>> status of
>>> the panel/zone it will show as open or trbl...which confuses the hell
>>> outta
>>> me, so I always put eols on unused zones.
>>>
>
> You can program to not hsow in any partitions, but as Crash said it still
> shows when viewing remotely or via laptop and cna be confusing.
>
>
> --
> Bob La Londe
>
> Cheapskate's Ways to Do Fishing Stuff
> (The Frugal Fisherman)
> Through the Month of October 2005
>