[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: FBII XL-2 question



"Frank Olson" <Use_the_email_links@xxxxxxxxxxxxxxxxxxxxxx> wrote in message
news:IOftf.221632$Gd6.215924@xxxxxxxxxxx
> Charles Schuler wrote:
>> The keypad arms the system (by entering the user code ... the arm light
>> comes on) but no alarm sounds when the house is entered.  The strange
>> thing is that "instant + stay + user code" works as expected..  This
>> system was in the house when I moved here and no documentation is
>> available.  The keypads are XL4600SMs.
>>
>> Thanks in advance!
>
>
> Did you wait for the exit delay to expire??  It's usually sixty seconds
> (but could be anything between 30 and 120 seconds).  If you arm the system
> using "instant + stay + user code" there is no exit delay as the system
> assumes no one's going to be leaving.  Also, check to make sure that any
> motion sensor you have is working by opening and closing the exit door
> after you arm the system with just the code.  The reason for this is that
> if the zone is set up as a "stay/away/follower" it will automatically
> bypass unless the exit door is cycled open then closed.

Yes, I waited.  No motion sensors.

Thanks Frank ... I guess it is some sort of problem with the main panel.
Can I buy one?




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home