Hi George
Sorry icreated an x10 command for hv instead of a macro.....
Have put a couple of more pics in the pic section of the list which i hope
will help...Currently when creating the action section when you select
gshed-hvision you cant select macro ??? create it using an output as i have
and then re edit once finished as per the edit pic....
Sorry about that
Frank
----- Original Message -----
From: "Frank Mc Alinden" <fmcalind@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Saturday, December 04, 2004 4:09 PM
Subject: Re: [ukha_xpl] Re: Could use some help with the HomeVision Plug In
>
> Hi George
>
> Using xPL Manager you need to highlight Determinators and
right
> click with the mouse.
> and click on New Determinator....This will bring up the Determinator
wizard
> so click on next..
> Then you are prompted to enter a name for the Determinator..and click
on
> next..
>
> Next comes up the section for programming the input condition(s) which
cause
> the Determinator to run, in your case a xpl w880 message...Click on
> add...Hopefully Mal has added a xml file for his plugin so you can
select
> the rf device for input conditions..IF NOT select gshed-hvision and
create
> the input condition using that...BUT you will need to re edit the
input
> condition after you have completed creating it so the source =
> mal-w800rf.w800com6.....
>
> Once the input condition is created click next which will bring you to
the
> ACTIONS ....Click on ADD and then select GSHED-HVISION and create the
> actions as required ..Then click finish and the Determinator is
> finished.......If input condition was created using gshed-hvision for
the
> input condition you need to re edit the input condition to reflect the
> mesage from your xpl rf plugin...
>
> I have put a couple of photos of the Condition and Action for the
event
> your trying to create in the photo section of the xpl yahoo
list...have a
> look......
>
> If when created the macro doesnt run in hv double check the
conditions ,
i
> usually find i have the
> wrong header there ie xpl-trig instead of xpl-stat and vice versa so
double
> check.....
>
> HTH
> Frank
>
>
>
>
>
> ----- Original Message -----
> From: "gmotichka" <gmotichka@xxxxxxx>
> To: <ukha_xpl@xxxxxxx>
> Sent: Saturday, December 04, 2004 11:35 AM
> Subject: [ukha_xpl] Re: Could use some help with the HomeVision Plug
In
>
>
> >
> >
> > That is generous of you Frank. Here is the what is received in
the
> > xPL Rx WIndow:
> >
> > xpl-trig
> > {
> > hop=1
> > source=mal-w800rf32.w800com6
> > target=*
> > }
> > x10.basic
> > {
> > command=on
> > device=M1
> > }
> >
> >
> > This x10 command triggers HV Macro
> > ID 14 AV ON
> >
> > Is that the info you need?
> >
> > George
> >
> >
> >
> > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<fmcalind@b...>
> > wrote:
> > > George
> > > Can you please copy and paste into an email the
w800
> > message
> > > thats received in xPL and email it to me and also the macro
in hv
> > you wish
> > > to run when its received and i will write up a determinator
for
> > you to
> > > try....later this afternoon
> > >
> > > Frank
> > >
> > >
> > > ----- Original Message -----
> > > From: "gmotichka" <gmotichka@h...>
> > > To: <ukha_xpl@xxxxxxx>
> > > Sent: Saturday, December 04, 2004 10:12 AM
> > > Subject: [ukha_xpl] Could use some help with the HomeVision
Plug In
> > >
> > >
> > > >
> > > >
> > > > I am a total newbie at this. With help from the folks
here I do
> > have
> > > > xPLmanager running and xPLw800 running.
> > > >
> > > > The main reason for getting the w800 was to eliminate
all the
> > > > individual receivers for x10. It must also interact
with
> > HomeVision
> > > > since I use some x10 code to kick off macros. That it
what I am
> > > > trying to get going here.
> > > >
> > > > I have the HVInput.hvx and HVExclue.hvx files. I also
have the
> > plug
> > > > in installed. I did read the doc file that came with
the plug in,
> > > > but I did not find it real clear (obviously from my
general
> > > > ignorance of this project).
> > > >
> > > > I do not want to get into a lot of duplicate programing
- i.e.
> > > > repeating programing I already have in HV. A couple
main funtions
> > > > would serve me well. One being to pass on an x10 signal
received
> > > > from the w800 to HV to execute, and when an x10 signal
is
> > received
> > > > that is associated with a macro in HV to run it.
> > > >
> > > > Once I get that running I will be able to play around
with other
> > > > posibilities, especially if I run the plug in in debug
mode to
> > > > follow what it happening..
> > > >
> > > > Thanks
> > > > George M
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > http://www.x
> > > pl.myby.co.uk
> > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > > Yahoo! Groups Links
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> >
> >
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe: ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|