[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: Re: Could use some help with the HomeVision Plug In
Hi George
Using xPL Manager you need to highlight Determinators and right
click with the mouse.
and click on New Determinator....This will bring up the Determinator wizard
so click on next..
Then you are prompted to enter a name for the Determinator..and click on
next..
Next comes up the section for programming the input condition(s) which
cause
the Determinator to run, in your case a xpl w880 message...Click on
add...Hopefully Mal has added a xml file for his plugin so you can select
the rf device for input conditions..IF NOT select gshed-hvision and create
the input condition using that...BUT you will need to re edit the input
condition after you have completed creating it so the source =
mal-w800rf.w800com6.....
Once the input condition is created click next which will bring you to the
ACTIONS ....Click on ADD and then select GSHED-HVISION and create the
actions as required ..Then click finish and the Determinator is
finished.......If input condition was created using gshed-hvision for the
input condition you need to re edit the input condition to reflect the
mesage from your xpl rf plugin...
I have put a couple of photos of the Condition and Action for the event
your trying to create in the photo section of the xpl yahoo list...have a
look......
If when created the macro doesnt run in hv double check the conditions , i
usually find i have the
wrong header there ie xpl-trig instead of xpl-stat and vice versa so double
check.....
HTH
Frank
----- Original Message -----
From: "gmotichka" <gmotichka@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Saturday, December 04, 2004 11:35 AM
Subject: [ukha_xpl] Re: Could use some help with the HomeVision Plug In
>
>
> That is generous of you Frank. Here is the what is received in the
> xPL Rx WIndow:
>
> xpl-trig
> {
> hop=1
> source=mal-w800rf32.w800com6
> target=*
> }
> x10.basic
> {
> command=on
> device=M1
> }
>
>
> This x10 command triggers HV Macro
> ID 14 AV ON
>
> Is that the info you need?
>
> George
>
>
>
> --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<fmcalind@b...>
> wrote:
> > George
> > Can you please copy and paste into an email the w800
> message
> > thats received in xPL and email it to me and also the macro in hv
> you wish
> > to run when its received and i will write up a determinator for
> you to
> > try....later this afternoon
> >
> > Frank
> >
> >
> > ----- Original Message -----
> > From: "gmotichka" <gmotichka@h...>
> > To: <ukha_xpl@xxxxxxx>
> > Sent: Saturday, December 04, 2004 10:12 AM
> > Subject: [ukha_xpl] Could use some help with the HomeVision Plug
In
> >
> >
> > >
> > >
> > > I am a total newbie at this. With help from the folks here I
do
> have
> > > xPLmanager running and xPLw800 running.
> > >
> > > The main reason for getting the w800 was to eliminate all
the
> > > individual receivers for x10. It must also interact with
> HomeVision
> > > since I use some x10 code to kick off macros. That it what I
am
> > > trying to get going here.
> > >
> > > I have the HVInput.hvx and HVExclue.hvx files. I also have
the
> plug
> > > in installed. I did read the doc file that came with the
plug in,
> > > but I did not find it real clear (obviously from my general
> > > ignorance of this project).
> > >
> > > I do not want to get into a lot of duplicate programing -
i.e.
> > > repeating programing I already have in HV. A couple main
funtions
> > > would serve me well. One being to pass on an x10 signal
received
> > > from the w800 to HV to execute, and when an x10 signal is
> received
> > > that is associated with a macro in HV to run it.
> > >
> > > Once I get that running I will be able to play around with
other
> > > posibilities, especially if I run the plug in in debug mode
to
> > > follow what it happening..
> > >
> > > Thanks
> > > George M
> > >
> > >
> > >
> > >
> > >
> > >
> > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.x
> > pl.myby.co.uk
> > > To Post a Message: ukha_xpl@xxxxxxx
> > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > Yahoo! Groups Links
> > >
> > >
> > >
> > >
> > >
> > >
> > >
>
>
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe: ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|