RE: Re: xPLHAL INSTALL


  • Subject: RE: Re: xPLHAL INSTALL
  • From: Tony Tofts
  • Date: Fri, 10 Oct 2003 09:43:00 +0000

> Im a little concerned how my pic is going to handle the
> Exclusive/Release commands as that means it need to store the source
> each time a message is received for future checking.....Wouldnt want
> to miss the Release Command either !!
>

It isn't compulsory to support them, just need to ensure people are aware
of
the fact.

> Also can i stipulate that my DELAY is 1 to 60 seconds?? and 0 = do
> not clear as per the schema?????

Not sure I follow the question, but if you mean can you stipulate a
maxmimum
time of 60 then yes.

> Is the OSD.CONFIRM command really necessary to implement with
> pics ...?? and are people using this command??????? Im sure its nice
> and easy to implement on a pc .....

I don't think it's compulsory, Ian can confirm?

> > Really you shouldn't be looking for hop= anything in particular,
> as it's
> > value is irrelevant to the receiver.
>
> Oh i wasnt aware of that ...Is it only the Bridges that are
> concerned with Hops ..??

Really yes, since only a bridge increments the hops then only a bridge
_has_
to check if it goes > 10
That doesn't mean you can't check this if you want to

The message to your pic could contain hop=1 thru hop=10 when it arrives,
since it could of passed over many bridges.

Regards
Tony







xPL Main Index | xPL Thread Index | xPL Home | Archives Home