[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Problem in the xpl Bridging of Floorplan
- Subject: Problem in the xpl Bridging of Floorplan
- From: "glhopital" <glhopital@xxxxxxxxx>
- Date: Mon, 05 Feb 2007 13:10:25 -0000
In the translated source produced buy floorplan there is an extra
space introduced between "xpl." and the xplhal name.
Here is what I've got in xap message display :
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><
Error Message: Invalid name/value pairing. No part of the address
value may contain space characters
Message Line#: 7 - source=xpl. xpl.xplhal.0703wxp1
Received From: 172.24.1.57:2989
xap-header
{
v=12
hop=1
uid=FFA03A00
class=xpl.x10
source=xpl. xpl.xplhal.0703wxp1
}
cmnd.basic
{
command=ON
device=A1
}
The error that was generated is as follows:
Problem reading xAP message.
Source: xAPMessage
Problem reading xAP message.
Invalid name/value pairing
No part of the address value may contain space characters.
KCS.xAP.Framework.xAPMessageReaderException: Problem reading xAP
message. ---> KCS.xAP.Framework.xAPInvalidMessageException: Invalid
name/value pairing
No part of the address value may contain space characters
at
KCS.xAP.Framework.Message.xAPMessageReader.ReadHeaderPair(xAPMessage
message, String line)
at KCS.xAP.Framework.Message.xAPMessageReader.ReadMessage()
--- End of inner exception stack trace ---
at KCS.xAP.Framework.Message.xAPMessageReader.ReadMessage()
at KCS.xAP.Framework.Transport.xAPListener.OnReceive(IAsyncResult ar)
xAP_Automation Main Index |
xAP_Automation Thread Index |
xAP_Automation Home |
Archives Home
|