RE: Node 1 -> Node 0 : What other cables can I add ?
- Subject: RE: Node 1 -> Node 0 : What other cables can I
add ?
- From: "Nigel Giddings" <nigel@xxxxxxxxxxxxxx>
- Date: Thu, 22 Jun 2006 10:36:31 +0100
It's difficult to tell from your description but have you considered
condui=
ts or some other form of cable route?
=20
It obviously depends on the location of the spaces and what is between but
=
if at all possible installing two cable routes, one for power circuits and
=
another for signal cables would allow you to deal with future unknowns.
=20
Houses don't tend to allow for changes to the wiring infrastructure
without=
redecoration, a pet hate of mine which I have tried to overcome in my new =
build with risers, cable tray and trunking. Even running cables through
the=
se routes takes me a while...
=20
If you could run conduits, waste pipe (available in many sizes from
1=BC" u=
pto and beyond 4") with 45 degree swept bends to allow cables to be
pulled =
in the future...
=20
HYPERLINK "http://photos.corbenic.co.uk/photos/photo174.html"http://photos.=
corbenic.co.uk/photos/photo174.html
=20
HYPERLINK "http://photos.corbenic.co.uk/photos/photo223.html"http://photos.=
corbenic.co.uk/photos/photo223.html
=20
HYPERLINK "http://photos.corbenic.co.uk/photos/photo229.html"http://photos.=
corbenic.co.uk/photos/photo229.html
=20
HTH
=20
Nigel
=20
_____=20=20
From: noughtomate [mailto:balraj_jassal@xxxxxxx]=20
Sent: 22 June 2006 09:58
To: ukha_d@xxxxxxx
Subject: [ukha_d] Node 1 -> Node 0 : What other cables can I add ?
=20
Hi,
Just finsishing off my Home Cinema project(Node 1), and planning=20
ahead for cables to go to Node 0.
My Node 0 currently has :=20
- CCTV video server
- 802.11g Broadband Router Modem (but I prefer cabled)
- Comfort alarm & Home Automation system
>From Node 1 so far, I cabled for :=20
- 4 x CAT 6 (for MCE PC, Netgem iPlayer and spares)
- Telephone Wire (for Sky Box)
- Sky Cable (for Loftbox dsitribution)
- 6 core alarm cable (for Xantech IR distrubution. Possible=20
integration with Comfort)
Are there any other cables I should add ?
I really can't think of anything else, but I thought I should run it=20
by you guys!
=20
--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.394 / Virus Database: 268.9.2/372 - Release Date: 21/06/2006
--=20
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.394 / Virus Database: 268.9.2/372 - Release Date: 21/06/2006
=20
------oooo0oooo-------
22/6/2006
[Non-text portions of this message have been removed]
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|