The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Cat-5e



I had Cat5 buried under screed once - it was just laid in place with
no
capping or any other protective measures. Before the screed went down it
all
tested OK. After the screed a number of the links had shorts on them.

Keeping in mind that these had been terminated, tested and the plates
covered the only conclusion I came up with was that the the little sharp
stones in the screed had penetrated the sheaf and the insulation of some of
the inner conductors and somehow made the shorts. It seemed impossible to
me
so I removed the terminations and tested between the conductors with a
multimeter - they were still shorted.

It still seems unlikely but I have no other explanation and in future would
do as suggested - run in conduit for greatest flexibility or at least put
capping over the top.

Regards,

David


On 4/11/06, Raymond Kelly <ray@xxxxxxx> wrote:
>
> On same topic. I am using Cat5e for my dallas 1-Wire sensors and part
> of the cable run I want to bury in screed/concrete.
> Will this cable be OK in concrete without another covering?
> Cheers
>
> On 11/04/06, Chris Hunter <cjhunter@xxxxxxx> wrote:
> > TLC have Cat-5e on offer at 25GBP for 305m ... but I can't
remember if
> > that's a good price or not ? !
> >
> > Chris
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
> >
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>


[Non-text portions of this message have been removed]




UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.