Ade
I gave up years ago trying to put all the low voltage into the connector
blocks. My solution (not to everyone's taste, but it works), is to
locate a chocolate block with 7 connectors somewhere close in the hub
and fit-off everything I know that needs power into the first connector
and put a jumper across to the other 2. Ditto for common, leaving the
centre connector to avoid potential shorts. As the project draws to a
close or the client finally gets around to having that additional
PIR/Gate station installed, the other connectors are used to avoid
disturbing what is already working.
Your cry of anguish over fitting off Comfort (and other similar systems)
is an echo around the world.
Rod Stephens
Digihouse (Aust) Pty Ltd
-----Original Message-----
From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
Of Adrian
Sent: Sunday, 21 August 2005 5:56 PM
To: ukha_d@xxxxxxx
Subject: [ukha_d] how do keep common connections tidy?
Hi
Am currently wiring up my comfort alarm (this could apply to lots of
things), how have you managed to keep the +VE and common tidy?
I guess what i'm after is something like a miniature bus bar for + and -
, i originally tried jamming them all into the connectors on the board
but this is untidy and also a pain when you want to add one and some
fall out.
any thoughts/ideas/links?
Ade