The consensus here at work is leakage from the carbon deposits due to
arcing
that occurs when the switch is operated.
A suitably rated 100K Ohm 1W resistor sounds like a reasonable solution,
alternatively a compatible dimmer switch or automated switch should do the
trick too
Replacing switches then asking people to only operate the switch at the
zero
crossing point of the mains :S
-----Original Message-----
From: Alex Monaghan [mailto:ha@xxxxxxx]
Sent: 25 April 2005 18:45
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] [OT] Low Energy Bulbs
Switch is in the live (I know as I ran the cables after ripping out the
huge
mess the previous owner had left !)
There's an earth in the rose, but only live / neutral to the bulb holder,
so
I guess that rules out an earth leakage.
> -----Original Message-----
> From: Jim Noble [mailto:yahoo-groups@xxxxxxx]
> Sent: Monday, April 25, 2005 6:07 PM
> To: ukha_d@xxxxxxx
> Subject: Re: [ukha_d] [OT] Low Energy Bulbs
>
>
> Alex Monaghan wrote:
>
> >
> > I'm not going mad then :) (well perhaps, but not because of
> the lights
> > !) Ours are normal switches - still waiting for approval to
install
> > some automation (something to do with lack of decorating
> over all the
> > bare plaster where I've installed cat5, coax & new ring main
cables
> > :)) Any solution ? We use the lounge as an additional
> bedroom when we
> > have the whole family over and I don't really want to have
> to change
> > the bulb when we have visitors.
>
>
> Do your lamp connections have an earth in the fitting? Is the
> switch in the live or the neutral line?
>
> I'm wondering if these low energy bulbs have a small leakage
> path to earth - if your light switches are on the neutral
> side it's possible the lamps are still "live" even when
turned off.
>
> I can't think of another reason why they would flash when
> switched off with a normal switch (lack of imagination a
> possible factor here...).
>
> Jim
>
>
>
> ------------------------ Yahoo! Groups Sponsor
> --------------------~--> Give the gift of life to a sick child.
> Support St. Jude Children's Research Hospital's 'Thanks & Giving.'
> http://us.click.yahoo.com/_HGP.B/6WnJAA/a8ILAA/IBOolB/TM
> --------------------------------------------------------------
> ------~->
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|