[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
RE: Velux Window Openers - A Possible Solution
- Subject: RE: Velux Window Openers - A Possible Solution
- From: "Rob Mouser" <groups@xxxxxxxxxxxx>
- Date: Mon, 8 Nov 2004 19:53:54 -0000
My velux windows are also "automated" using a velux pole ;-)
How would these attenuators work as the operation to open my windows
involves the pull down of a horizontal bar before the window will tilt and
=
I
cant see how you automate that? Or am I missing something?=20
=20
Many thanks,
=20
Rob
-----Original Message-----
From: Martin Howell [mailto:martin.howell@xxxxxxx]=20
Sent: 08 November 2004 18:57
To: ukha_d@xxxxxxx
Subject: Re: [ukha_d] Velux Window Openers - A Possible Solution
I looked at motorising my Veluxes some time ago and abandoned the idea=20
because Mr Velux wanted an arm and a leg for each one and I have 6=20
windows. Instead, I bought the manual opener - a pole with a hook on=20
the end - and it works fine. Moreover, it shows that the operation=20
movement is essentially linear, and a DIY solution using an electric or=20
pneumatic actuator should be pretty easy to rig up (and not expensive). =
=20
One of the things on my 'to do' list once the house is finished...
Martin
Neil Fuller wrote:
>Chaps
>
>I know the question of opening Velux windows automatically comes up
from
time to time.
>
>With an impending extension build coming up (Ho yin does do some nice
designs!), I've now researched the commercial actuator market and found the
following;
>
>www.secontrols.com
>
>They are the UK importers for the Italian made Mingardi range of
actuators=
=20
>
>http://www.mingardimagnetic.com/inglese/default.htm
>
>Mingardi also make a range of magnetic locks etc.
>
>The sales chap I spoke with said that the most expensive chain actuator
wa=
s
approx =A3150 so they seem somewhat cheaper than the Velux option too.
>
>A possible downside is that they fit on the frame rather than being
hidden
inside it but some would say that is a positive aspect when the things
brea=
k
down.
>
>A real plus point is that they accept standard signals (230v, 3 wire or
24=
v
reverse polarity) so no messing about with the Velux interface.
>
>SE controls also produce a control box that sits on a LON bus for
anyone
using that technology.
>
>Usual caveats of no association/interest apply.
>
>Regards
>
>Neil
>
>[Non-text portions of this message have been removed]
>
>
>
>
>
>=20
>Yahoo! Groups Links
>
>
>
>=20
>
>
>
>
>=20=20
>
=20
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|