--- In ukha_d@xxxxxxx, "John Andrews" <groups@j...> wrote:

> Don't go for wireless, just take 5 volts from the PC through
> the door bell contact and then to the parralel port - thus
> when someone presses the door bell, the parralel port will
> go high.

Just a bit of general advice as to connecting random contacts to
inport ports - always use a pull up resistor, and the contact to
short to earth when something happens.  This reduces (and generally
eliminates) noise pickup, and reduces chances of capacitive coupled
spikes killing something.  Just a 1K resistor to 5V is all thats
needed.

Oh yes - you need to turn your software upside down, as "on"
becomes "low".

David.