Re: Need help with my CP290



Carl wrote:
> ...over the weekend my PC crashed and I had to
> restore it to like new out of the box.   When I tried to use the CP290 I
> can't get any communications between the serial port and the unit.  It used
> to work on Com 4.
> ...
> I'm sending commands via the CP290 again, so unless
> something else goes wrong, I'm good.

I'm glad to hear that your CP290 is on the air again. At some point you might
want to do some preventive maintenance by replacing the electrolytic capacitors
in that unit.  My CP290 is 1985 vintage and I had to change the capacitors back
in 2001. Check the date code on the capacitor labels.  There are six to change
and they're not expensive. I think all are radial, 85 degree C units.

Designator/Capacity (mfd)/Voltage (vdc)
C3/100/25
C4/1,000/25
C5/220/25
C7/100/10
C6/100/10
C15/1/50

--
Chuck