Yes, that's right, in the US we use "split single phase" service which,
at the meter, is delivered as two 180 degree legs out of phase by 180
degrees. So, if you have two 60 Hz 120v phases 180 degrees apart these
will work. That is NOT the same as two phases of 3 phase service which
would only be 120 degrees apart.
From:none
none@xxxxxxxxxx
> "BruceR" <br@xxxxxxxxxxxxxxxx> wrote in message
> news:lU%Df.3590$Jg.656@xxxxxxxxxxxxxxxxxxxxxxx
>> It will handle 2 phases fine just not 3 phase which is generally only
>> found in larger industrial locations.
>
> Well, it'll handle split phase 120V/240V, this is still considered
> single
> phase, and is not two phase.
>
>
>