[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC 832 - how to reset?



I try to use this config with :
partition 2 activated for smokes
but somethings don't work....

-I don't receive call if the alarm is triggered for the partition 2
-when my keyboard is in saver mode, i need to choose a partition ( I
want see all errors, alarm, etc. at the same place is for this reason I
activate Global keyboard)

Sec. 000  -> pc55xxz -> 01 (global)
Sec. 000  -> lcd5500z -> 08 (global)
Sec. 160  ->  002
Sec. 161  ->  010
Sec. 201  -> 1
Sec. 202  -> 12345678 (13 zones total, 9 intrusions, 4 smokes)
Sec. 203  -> 1
Sec. 207  -> 2345
Sec. 301  -> D<my cell number>EEE1E2E1E2E1E2E1E1F
(bip....bip....bip....)
Sec. 302  -> D<my cell number>EEE111111111111111F
(biiiiiiiiiiiiiiiiiiiiip)
Sec. 310  -> A218
Sec. 311  -> A219
Sec. 320  -> 31 32 33 34 35 36 37 38
Sec. 321  -> 39 21 22 23 24
Sec. 360  -> 05 05
Sec. 361  -> 1xxxxxxx (intrusions alarm on 1st telephone #)
Sec. 362  -> x1xxxxxx (smokes alarm on 2nd telephone #)
Sec. 380  -> 1xx1xxxx (touch tone enabled)
Sec. 381  -> xxxx1xxx (do I put #6 enabled ?)


--
JOBINE