Re: Question for Robert Bass
> So, for example, does it have an instant home/away
> zone type? (Interestingly, the version of MAXSYS
> I have does not support this type. Its home/away
> zones have to be followers/interiors or delays.)
Maxsys was primarily targeted at the commercial market, hence the lack of
certain features. Here's a list of available zone types on the Digiplex:
0 - Disabled (Default)
1 - Entry Delay 1
2 - Entry Delay 2
3 - Entry Delay 3
4 - Entry Delay 4
5 - Follow
6 - Instant
7 - 24Hr Buzzer
8 - 24Hr Burglary
9 - Delayed 24Hr Fire
A - Standard 24Hr Fire
B - Stay Delay 1
C - Stay Delay 2
D - Stay Delay 3
E - Stay Delay 4
Following are the available zone options:
[1] Auto Zone Shutdown
[2] Bypass Zone (Default)
[3] Stay Zone
[4] Force Zone
[5] [6] Zone Alarm Type
off off Alarm (steady)
off on Audible Alarm (pulsed)
on off Silent Alarm
on on Generates only a report
[7] Intellizone
[8] Delay before transmission
--
Regards,
Robert L Bass
=============================>
Bass Home Electronics
2291 Pine View Circle
Sarasota · Florida · 34231
877-722-8900 Sales & Tech Support
http://www.bassburglaralarms.com
=============================>