[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: VONK Format
- Subject: Re: VONK Format
- From: KJ7BZC <herbertclan4@xxxxxxxxx>
- Date: Sun, 5 Feb 2023 22:41:11 -0800 (PST)
- Newsgroups: alt.security.alarms
- References: <050ee40a-57a7-40f6-9f33-bbf490a23450n@googlegroups.com>
On Sunday, January 29, 2023 at 2:54:23 PM UTC-7, xastr115 wrote:
> Hello all,=20
>=20
> Recently I've been looking through documentation for Sur-Gard and Connett=
ix central station receivers, and noticed a mention of a format that is ref=
erred to as "VONK." I've never heard of this protocol anywhere outside of t=
hese guides, and searches to Google with a variety of supplementary keyword=
s have not been successful in turning up more info about what kind of panel=
s send this format. Are any of you here familiar with VONK?=20
>=20
> Thank you!
I've been wondering about that too, it's 110 baud using standard CCITT tone=
pairs. 2 digit account number, and a number of status channels similar to =
what Scancom and Ademco High Speed send. No handshake sent from the receive=
r, which is interesting. If you find any panels that use it, I'd be interes=
ted to know as well.
Keith