[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: pc 1550 need to reset after disconnecting sensor and then connecting
On 4/25/2015 6:38 PM, jgoodjr wrote:
> I disconnected a glass break sensor and then reconnected it, zone light
> stays
> on, I need to reset system.
>
>
Try *7. If that doesn't work, remove the red power wire for a few
seconds, then put it back on. If that doesn't work check how you wired
the glassbreak.
You should be be using + - C NC on the glassbreak.
Is the End Of Line resistor in use? If so use C NO with the resistor
across C NO also. You can use C NC if you series in the resistor.
So many minor things to look for. It could also be the zone you are
using is programmed for something other than a burg zone.
--
Jim Rojas
Technical Manuals Online!
http://www.tech-man.com
8002 Cornwall Lane
Tampa, FL 33615-4604
813-884-6335
813-440-6653 Fax
Email: jrojas@xxxxxxxxxxxx
AOL: rojas813
MSN: jimrojas@xxxxxxxxxxx
Yahoo: jimrojas
ICQ: 20116219
GoogleTalk: Rojas813@xxxxxxxxx
--- news://freenews.netfront.net/ - complaints: news@xxxxxxxxxxxx ---