[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: NX v2 change user codes



"proguard" <sp.kintzonides@xxxxxxxxxxx> wrote in message
news:7e602aeb-4b35-4e44-8c2c-2d0c900db3a0@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
On 20 ???, 23:28, "Techvoid" <n...@xxxxxxxxxxxx> wrote:
> "proguard" <sp.kintzoni...@xxxxxxxxxxx> wrote in message
>
> news:a8156738-b8ef-463e-8108-3c5be8b6463a@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> On 20 , 18:52, "Techvoid" <n...@xxxxxxxxxxxx> wrote:
>
>
>
>
>
> > "proguard" <sp.kintzoni...@xxxxxxxxxxx> wrote in message
>
> >news:4d0b3252-08ed-4fb7-882c-2ca21d181aab@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>
> > > Recently after an installation of a new NX4 v2 and a new NX8 v2 i
> > > found that i can't change master code or add a new user i.e. user #2
> > > from keypad. Only changes apply from DL900.
> > > Am i missing something? I did it with standart procedure (*5 master
> > > code 01 new code #)
> > > Any idea?
> > > thanks in advance
>
> > *5 master code
> > user #--------02
> > new code
> > #
>
> i did just like that but after *5 master code the ready light does not
> blinks.....
>
> which code are you using as master?- ???????? ???????? ?? ???????? -
>
> - ???????? ???????? ?? ???????? -

I am using user#1 with code 1234 and authority level cheked as master
with access at all partitions even if i have only 1 partition...
I am using DL900 its the only way to change code. But as you can
understand the client want to change it by himself.

try:
*6 1234
01

make sure light 4 is on,

*
make sure light 1 is on,

#.

then try setting code again.




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home