Re: home alarm system?



"Mark Leuck" wrote:
>
> The PC1550 was the v3 model of the 1500 wasn't it? If so it did have the
> lockout feature


To reset the Installer's code to 1500
Power up the panel. Short the "default" pins. Enter 80000. Remove the short.
Enter 91. Enter 20 1500 ##.

--

Regards,
Robert L Bass

==============================>
Bass Home Electronics
4883 Fallcrest Circle
Sarasota · Florida · 34233
http://www.bassburglaralarms.com
Sales & Tech Support 941-925-8650
Customer Service 941-870-2310
Fax 941-870-3252
==============================>