Re: Intellisense FG-730 on Napco P3200



The FG-730 is a very good GBD in my opinion. GBDs should be on a non-24 hour
burg zone. If it's a residential system, especially with pets or kids, then
make it an interior zone, if the GBD is anywhere near a keypad then an
interior follower zone might be best.

"t nguyen" <tnmissilen@xxxxxxxxx> wrote in message
news:ixHIi.123$d02.106@xxxxxxxxxxxxxxx
> Hello, I have installed a FG-730 on Napco p3200 with the following
> parameters
> NC loop with default 750ms response.
> programmed zone as 24 hr zone
> did not connect any wires to the tamper terminal
>
> Everything was looking fine until I tested that glassbreak sensor with C&K
> simulator.  The alarm went off as expected but after I disarmed the
> system, the panel was still in alarm condition on the glassbreak zone.
> The keypad displayed as system ready but the siren still went off.  Not
> sure what is going here.  Could it be bad FG-730 or I did not program the
> panel correctly?  I tried to change the zone type to a normal burg zone
> (not 24 hr) then it was ok.
>
> Thank you for your help
>
>
>