[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Window Foil



Matthew Stanley wrote:
> A customer I have that I took over 3 years ago had a newer DSC system
> installed. I added a DSC acuity 100 GBD ontop of the door contact, DV300
> motion and Window Foil they already had. The GBD was on its own zone. During
> the night, some kids took a brick and smashed out the front display window.
> The glass break didnt go off. However, the window did sound the alarm. The
> bell started to ring in the front of the store and scared them away. Now the
> strage thing is, I tested the GBD with DSC's handheld tester and it work
> when installed. When I went back to check it, It failed.
>
> To this date, I will use DSC panels, Motions, but no Glass Break Detectors.
> I now use Rokonet.(however, I dont use their motions) So I was kinda glad
> that I kept the window foil connected. In the past I always disconnected the
> crap if I took an account over and installed GBD's. But now, if it works, I
> keep it connected. Then, if a window has been smashed and they replace it, I
> will foil the window to match the rest of the windows.
>
> M


On the older model DSC glass breaks they used to attach the microphone
to the cct board via really thin red and black wires (on the order of
32AWG).  If you weren't careful mounting the unit, you'd break one of
the wires.  If you didn't test the unit (using their tester), you'd
never know the unit didn't work.  We recently took over a system in a
restaurant that employed these older units.  3 out of the 6 installed
had broken wires.


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home