Re: Ademco Lynx Zone Customization?



Why don't you just arm away? Unless the panel switches back to stay if
it doesn't detect an exit door, then it will work fine. You can also use
  MAX mode, which is code + 4, which also removes the delay from the
entry doors.

Jim Rojas



briansgooglegroupemail@xxxxxxxxx wrote:
> On Aug 20, 12:23 am, Frank Olson <Use-the-email-
> li...@xxxxxxxxxxxxxxxxxxxxxx> wrote:
>> briansgooglegroupem...@xxxxxxxxx wrote:
>>> Hello,
>>> On an Ademco Lynx REN system, is there any way to make an Interior
>>> Follower zone arm in "Instant" mode.  Normally Interior Follower zones
>>> arm only in "Away" mode.
>>> Thanks in advance.
>> Is it only the one zone you're trying to arm?  How many more are
>> programmed as "interior follower"?
>
> Frank, no, I'm trying to arm all zones.  I only have a single motion
> detector, and it is an interior follower zone.  All other zones are
> either perimeter or entry/exit.  The Lynx has three arming modes:
> Away, Stay, and Instant (or Stay-Instant).  Since Stay and Instant are
> both "stay" modes, they don't arm the interior followers.  Well, I'd
> like to use "Instant" as my night mode and would like the motion
> detector armed at night since nobody should be walking around
> downstairs where it is located.
>
> Thanks!
>